Product compatibility
Fits both DL-6 and VanDOOR AluLIFT.
Reference verified on the VanDOOR ranges below. Any out-of-scope install requires engineering validation.
Compatible range

Lifecycle
Annual
Cadence pulled from manufacturer manuals. Preventive maintenance recommended to preserve torque, sealing and operator safety.
Technical specifications
2 documented specifications
Headline spec
Quantity
Additional data
Product compatibility
Reference verified on the VanDOOR ranges below. Any out-of-scope install requires engineering validation.
Compatible range
Related documentation
Manuals and datasheets referenced for this part.
Part FAQ
The four guiding blocks (ref. DL-8001254) must be replaced at every annual inspection. They are the highest-frequency consumable in the system — one system = four blocks per year. Replacement is explicitly listed in both ranges' maintenance schedules (DL-6 and AluLIFT). The part is common to both. Keep a few sets in stock at the workshop if you operate more than 5 equipped vehicles.
SRCFR---Manuel-utilisateur-DL-6.mdl.471-472 + maintenance l.425, l.585
High-frequency consumables: DL-8001254 guiding blocks — set of 4 per system per year; A23 12V batteries for FOB remote — 1 to 2/year per FOB. Fatigue parts to anticipate: DL-8001252 drive gear — replacement every 5 years or 160,000 cycles; AluLIFT balancer — every 1.5 to 2 years. Incident-critical parts: emergency-release cable, 30 A fuse, 2.5 m battery cable. The full motor block is replaced at end-of-system-life (16 years theoretical at standard usage).
SRCANALYSIS.mdl.section 3
Parts common to both ranges: motor block, control box, REED limit-switch sensors, FOB remote and A23 battery, battery cable, profile cable, 30 A fuse, DL-8001254 blocks, DL-8001252 drive gear, release key and cylinder. AluLIFT-specific parts: 5 push-button references (DL-8000810/811/814/815/816), spring balancer, door panels, vertical and horizontal rails, cable drums. Note: in EN documentation the drive gear is listed as DL-8002152 — confirm with VanDOOR (likely typo, correct reference is DL-8001252).
SRCANALYSIS.mdl.section 2 + 9
Field essentials
Critical procedures to stay operational — emergency release and installer qualification.
External release procedure: (1) insert the DoorLIFT key into the lock cylinder at the centre of the intermediate or top panel, outside face; (2) turn the key 90° clockwise and firmly pull the lock and cable out of the cylinder — the system disengages; (3) reinsert the cable and cylinder into the door lock housing, then operate the door by hand. On the AluLIFT, an internal release is available: pull the red sleeve marked 'EMERGENCY DOOR RELEASE' to disengage the motor lever from inside the box.
SRCFR---Manuel-utilisateur-DL-6.mdl.617-632 + utilisation l.420-449
VanDOOR does not perform installation itself. AluLIFT integration must be carried out exclusively by qualified, trained bodybuilders or integrators, in accordance with Machinery Directive 2006/42/EC and best practice. The integrator guarantees regulatory compliance of the final assembly, verifies correct operation, commissions the system, and supplies the end user with the manual and CE Declaration of Conformity for the integrated equipment.
SRCManuel-instruction-installation.mdl.45-72